Vitruvius sets forth specifications for the site orientation and lighting of baths, the efficient juxtaposition of men's and women's quarters, the construction of hypocaust floors and moisture-resistant double vaults, chamber and basin proportions, and the circular design and temperature control of the laconicum.
Primum eligendus locus est quam calidissimus, id est aversus ab septentrione et aquilone. ipsa autem caldaria tepidariaque lumen habeant ab occidente hiberno, si autem natura loci inpedierit, utique a meridie, quod maxime tempus lavandi a meridiano ad vesperum est constitutum. et item est animadvertendum, uti caldaria muliebria et virilia coniuncta et in isdem regionibus sint conlocata; sic enim efficietur, ut vasaria et hypocausis communis sit eorum utrisque. aenea supra hypocausim tria sunt componenda, unum caldarium, alterum tepidarium, tertium frigidarium, et ita conlocanda, uti, ex tepidario in caldarium quantum aquae caldae exierit, influat de frigidario in tepidarium ad eundem modum,1 testudinesque alveolorum ex communi hypocausi calfaciantur.
First, the warmest possible site must be selected, that is, turned away from the north and northeast. The hot rooms and warm rooms themselves should have their light from the winter sunset, or if the nature of the terrain should prevent this, at all events from the south, because the proper time for bathing has been established principally from midday until evening. Care must also be taken that the hot rooms for women and men be placed adjacent and in the same quarters; for in this way it will be brought about that the boiler room and the hypocaust will be common to both. Three bronze cauldrons are to be placed above the hypocaust: one for hot water, a second for warm, and a third for cold, and they are to be so arranged that whatever amount of hot water has flowed out from the warm cauldron into the hot cauldron, the same amount flows in from the cold into the warm in like manner, and the curved vaults over the basins are heated from the common hypocaust.
Suspensurae caldariorum ita sunt faciendae, ut primum sesquipedalibus tegulis solum sternatur inclinatum ad hypocausim, uti pila, cum mittatur, non possit intro resistere, sed rursus redeat ad praefurnium ipsa per se; ita flamma facilius pervagabitur sub suspensione. supraque laterculis besalibus pilae struantur ita dispositae, uti bipedales tegulae possint supra esse conlocatae; altitudinem autem pilae habeant pedes duo. eaeque struantur argilla cum capillo subacta, supraque conlocentur tegulae bipedales, quae sustineant pavimentum.
The suspended floors of the hot rooms are to be constructed in such a way that first the ground is paved with eighteen-inch tiles sloping down toward the hypocaust, so that when a ball is thrown in, it cannot stop inside, but returns of its own accord back to the furnace mouth; thus the flame will spread more easily beneath the suspended floor. Above this, pillars are built of eight-inch bricks, so arranged that two-foot tiles can be placed upon them; moreover, the pillars are to have a height of two feet. They are to be built with clay kneaded with hair, and upon them are placed the two-foot tiles that support the pavement.
Concamarationes vero si ex structura factae fuerint, erunt utiliores; sin autem contignationes fuerint, figlinum opus subiciatur. sed hoc ita erit faciendum. regulae ferreae aut arcus fiant, eaeque uncinis ferreis ad contignationem suspendantur quam creberrimis; eaeque regulae sive arcus ita disponantur, uti tegulae sine marginibus sedere in duabus invehique possint, et ita totae concamarationes in ferro nitentes sint perfectae. earumque camararum superiora coagmenta ex argilla cum capillo subacta liniantur; inferior autem pars, quae ad pavimentum spectat, primum testa cum calce trullizetur, deinde opere albario sive tectorio poliatur. eaeque camarae in caldariis si duplices factae fuerint, meliorem habebunt usum; non enim a vapore umor corrumpere poterit materiem contignationis, sed inter duas camaras vagabitur.
As for the vaulted ceilings, if they are made of masonry, they will be more serviceable; but if they are of timber frame, tile work should be set beneath. But this will have to be done as follows: iron bars or arches should be made, and these hung from the timber frame with iron hooks placed as closely together as possible; and these bars or arches are to be so arranged that flat borderless tiles can rest and be borne upon two of them, and thus the entire vaulted ceilings are completed resting upon the ironwork. The upper joints of these vaults are to be smeared with clay kneaded with hair; but the lower part, which faces the pavement, is first to be rough-cast with lime mixed with pounded potsherd, and then polished with stucco or fine plaster finish. If these vaults in the hot rooms are made double, they will have a better utility; for moisture from the steam will not be able to rot the timber of the ceiling joists, but will circulate between the two vaults.
Magnitudines autem balneorum videntur fieri pro copia hominum sint ita compositae. quanta longitudo fuerit tertia dempta, latitudo sit,2 praeter scholam labri et alvei. labrum utique sub lumine faciundum videtur, ne stantes circum suis umbris obscurent lucem. scholas autem labrorum ita fieri oportet spatiosas, uti, cum priores occupaverint loca circum, expectantes reliqui recte stare possint. alvei autem latitudo inter parietem et pluteum ne minus sit pedes senos, ut gradus inferior inde auferat et pulvinus duos pedes.
The dimensions of the baths, which seem to depend on the number of people, should be arranged as follows: the width should be whatever the length is, less one third, not including the alcove of the washing basin and the tub. The basin seems proper to be placed under the window by all means, lest those standing around darken the light with their shadows. Moreover, the alcoves for the basins must be made sufficiently spacious so that, when the first comers have occupied the places around, the rest who are waiting may be able to stand properly. The width of the tub between the wall and the breastwork should be not less than six feet, so that the lower step and the ledge take away two feet from that space.
Laconicum sudationesque sunt coniungendae tepidario; eaeque quam latae fuerint, tantam altitudinem habeant ad imam curvaturam hemisphaerii.3 mediumque lumen in hemisphaerio relinquatur, ex eoque clipeum aeneum catenis pendeat, per cuius reductiones et demissiones perficietur sudationis temperatura. ipsumque ad circinum fieri oportere videtur, ut aequaliter a medio flammae vaporisque vis per curvaturae rotundationes pervagetur.
The Laconicum and sweating rooms are to be joined to the warm room; and they should have a height up to the bottom of the curvature of the hemisphere equal to their width. A central opening is to be left in the hemisphere, from which a bronze shield is to hang by chains; by the raising and lowering of this shield, the regulation of the temperature of the sweating room will be accomplished. It seems proper that the room itself should be laid out circular, so that the force of the flame and steam may circulate evenly from the centre throughout the curves of the round structure.
- 5.10.1quantum aquae caldae exierit, influat de frigidario in tepidarium ad eundem modum
A correlative clause in which the correlative demonstrative pronoun (tantum) governing "influat" is omitted in the main clause, corresponding to "quantum aquae caldae exierit". It describes an interconnected water replenishment system: as much hot water as is drawn from the warm cauldron into the hot, an equal amount of cold water automatically flows into the warm.
- 5.10.4quanta longitudo fuerit tertia dempta, latitudo sit
A proportional formula involving an ablative absolute. "Tertia dempta" ("a third having been deducted") qualifies the relative clause "quanta longitudo fuerit" ("whatever the length shall be"), specifying that the width ("latitudo sit") is to equal two-thirds of the length (a 3:2 proportion).
- 5.10.5ad imam curvaturam hemisphaerii
"Ad" with the superlative adjective "ima" denotes the vertical limit: "to the bottom/lowest part of the curve of the hemisphere", meaning the springing line where the domed vault begins to curve inward from the upright wall. Vitruvius specifies that the height of the vertical wall up to this springing line should equal the room's diameter (width).